WATER COMING THROUGH THE CEILING OF A RETAIL UNIT

Calgary · August 2026

  • MATERIALMODIFIED BITUMEN / BUILT-UP FLAT ROOF — ASSESSED, NOT REPLACED
CALGARY CREW · OPEN BOOKING
THE JOB

Water was coming through the ceiling inside the store. The roof told the rest of it: standing water pooled around the rooftop AC unit days after the last rain, and curb flashing that had let go at the corner. That distinction is the whole job. The membrane wasn't the root cause — the drainage was. Water that sits on a flat roof works into every seam it can find, and in Calgary it freezes and does it again every cycle. Re-covering the membrane without correcting the drainage would have been resurfacing the problem rather than solving it, and the leak would have come back.

WHAT WE DOCUMENTED

Interior first, then the roof, so the report reads from the symptom to the cause rather than asserting a conclusion. Ponding was photographed where it stood — that is the finding a report either captures or loses, because it is invisible three dry days later.

Before

Standing water pooled around a rooftop air conditioning unit on a Calgary flat roof
Ponding around the rooftop unit, days after the last rain.
Ponding water across a commercial flat roof field beside rooftop mechanical equipment
Failed curb flashing on a commercial flat roof, marked in chalk for the report
Curb flashing let go at the corner — marked for the report.
Mastic pitch pocket around a roof penetration on a commercial flat roof
RELATED
NOT READY TO TYPE AN ADDRESS?

WE'LL GET BACK TO YOU.

Drop your name and a way to reach you. We'll follow up with next steps — no pressure, no sales call.

OR REACH US DIRECTLY
EMAILcontact@bigboyroofing.ca
REACH THE CREW
FORM · CB

Giving us your number means you're okay with us calling or texting you about your roof — scheduling and quote updates, nothing else. Reply STOP anytime.

MESSAGE